Lack of standardized, reproducible protocols and reference values is among the challenges faced when using new or upgraded versions of instruments in reproductive laboratories and flow cytometry. Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay combined with flow cytometry routinely used for diagnostic measurement of sperm DNA fragmentation (SDF) is a unique example. Any change in the setting of the standard instrument, including upgrades of hardware or software, can lead to different results and may affect clinicians’ decision for treatment. Therefore, we compared TUNEL results of SDF obtained from a standard (C6) flow cytometer with a newer version of the same instrument (C6 Plus) and examined the cutoff, sensitivity, and specificity without calibration (adjustment) and after adjustment. Identical sperm preparation and matched acquisition settings were used to examine the performance of two flow cytometers. The strength of agreement of the results between the two observers was also assessed. After adjustment of the settings, overall concordance became high and the two cytometers showed 100% positive and negative predictive value with 100% area under the curve. The overall correlation coefficient observed between C6 and C6 Plus was highly significant (P < 0.0001; r = 0.992; 95% confidence interval [CI]: 0.982–0.997). After adjustment, the two cytometers showed very high precision of 98% and accuracy of >99%. The interobserver agreement on C6 flow cytometer for the two observers was 0.801 ± 0.062 and 0.746 ± 0.044 for C6 Plus. We demonstrated a strong agreement between the samples tested on the two flow cytometers after calibration and established the robustness of both instruments.
机译:在生殖实验室和流式细胞仪中使用新版或升级版仪器时,面临的挑战之一就是缺乏标准化的,可重复的实验方案和参考值。终端脱氧核苷酸转移酶dUTP缺口末端标记(TUNEL)分析与流式细胞术相结合,通常用于诊断精子DNA片段化(SDF)的测量是一个独特的例子。标准仪器设置的任何更改(包括硬件或软件的升级)都可能导致不同的结果,并可能影响临床医生的治疗决定。因此,我们将从标准(C6)流式细胞仪获得的SDF的TUNEL结果与同一仪器(C6 Plus)的较新版本进行了比较,并检查了未经校准(调整)和调整后的临界值,灵敏度和特异性。使用相同的精子制备和匹配的采集设置来检查两个流式细胞仪的性能。还评估了两个观察员之间结果一致的程度。调整设置后,总体一致性更高,两个细胞仪显示100%的阳性和阴性预测值,曲线下面积为100%。 C6和C6 Plus之间观察到的整体相关系数非常显着(P <0.0001; r ​​= 0.992; 95%置信区间[CI]:0.982–0.997)。调整后,两个细胞仪显示出非常高的准确度,达到98%,准确度> 99%。两位观察员在C6流式细胞仪上的观察员之间的共识是0.801±0.062和C6 Plus的0.746±0.044。校准后,我们​​证明了在两个流式细胞仪上测试的样品之间的强烈一致性,并建立了两种仪器的耐用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号