Bedside cardiopulmonary ultrasonography evaluates lung water content in very low-weight preterm neonates with patent ductus arteriosus

         

摘要

BACKGROUND Patent ductus arteriosus(PDA)is a common congenital heart abnormality in preterm neonates with a high incidence in neonates with very low birth weights.When PDA persists,interstitial lung water content increases,which could lead to abnormal circulation hemodynamics and pulmonary edema.It is important to perform early and reliable assessment of lung water content in very low-weight preterm neonates with persistent PDA.AIM To evaluate the role of bedside cardiopulmonary ultrasonography in the lung water content assessment in very low-weight preterm neonates with persistent PDA.METHODS From January 2018 to March 2020,69 very low-weight preterm neonates with echocardiography-confirmed PDA were selected as the PDA group.At the same time,89 very low-weight preterm neonates without PDA were randomly selected as the control group.All neonates underwent echocardiography and 6-segment lung ultrasonography on the fourth day after birth.The clinical characteristics and main ultrasonography results were compared between the two groups.Pearson’s analysis was used to analyze the correlation between lung ultrasonography score(LUS)and other related clinical and ultrasonography results in all neonates.In the PDA group,PDA diameters were recorded,and the correlation with LUS and left atrium to aortic(LA/AO)dimension ratio were also analyzed.LA/AO ratio is one of the ultrasonic diagnostic criteria for hemodynamically significant PDA.When the ratio is≥1.5,it suggests the possibility of hemodynamic changes in persistent PDA.A receiver operating characteristic curve was established using the sensitivity of LUS to predict the hemodynamic changes in neonates with PDA as the ordinate and 1-specificity as the abscissa.RESULTS A total of 158 neonates were enrolled in this study,including 69 in the PDA group and 89 in the control group.There were no statistical differences in sex,gestational age,birth weight,ventilator dependence,hospitalization length and left ventricular ejection fraction between the two groups(P>0.05).The LUS and LA/AO ratio in the PDA group were higher than those in the control group(P<0.05),but there was no difference of LUS in neonates with or without use of the ventilator(t=0.58,P=0.16).In all cases,LUS was negatively correlated with gestational age(r=-0.28,P<0.01)and birth weight(r=-0.36,P<0.01),while positively correlated with the LA/AO ratio(r=0.27,P<0.01).In the PDA group,PDA diameter was positively correlated with the LA/AO ratio(r=0.39,P<0.01)and LUS(r=0.31,P<0.01).Receiver operating characteristic results showed that LUS had the moderate accuracy for predicting hemodynamic changes in PDA(area under the curve=0.741;sensitivity=93.75%;specificity=50.94%).CONCLUSION Bedside cardiopulmonary ultrasonography can evaluate lung content in neonates with PDA and predict the possibility of hemodynamic changes in persistent PDA.

著录项

  • 来源
    《世界临床病例杂志》 |2021年第8期|P.1827-1834|共8页
  • 作者单位

    Department of Ultrasound Affiliated Hangzhou First People’s Hospital Zhejiang University School of Medicine Hangzhou 310006 Zhejiang Province China;

    Department of Ultrasound Affiliated Hangzhou First People’s Hospital Zhejiang University School of Medicine Hangzhou 310006 Zhejiang Province China;

    Department of Ultrasound Affiliated Hangzhou First People’s Hospital Zhejiang University School of Medicine Hangzhou 310006 Zhejiang Province China;

    Department of Ultrasound Affiliated Hangzhou First People’s Hospital Zhejiang University School of Medicine Hangzhou 310006 Zhejiang Province China;

    Department of Pediatrics Affiliated Hangzhou First People’s Hospital Zhejiang University School of Medicine Hangzhou 310006 Zhejiang Province China;

    Department of Pediatrics Affiliated Hangzhou First People’s Hospital Zhejiang University School of Medicine Hangzhou 310006 Zhejiang Province China;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 计算技术、计算机技术;
  • 关键词

    Patent ductus arteriosus; Cardiopulmonary; Ultrasonography; Lung ultrasound score; Very low-weight neonates; Preterm;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号