泰山抽水蓄能电站上水库存在渗漏情况,根据该电站长期观测资料,采用数值分析及现场测试等手段对电站上水库渗漏部位、渗漏量及防渗设施破损面积进行了系统分析研究,得到该电站上库不同部位的渗漏量及防渗设施破损面积的定量值,与实测值对比较为吻合.研究成果可为电站进行渗漏治理提供理论依据.%Long-term observations show that there is leakage in the upper reservoir of Taishan Pumped-storage Power Station.In order to analyze leakage location,seepage quantity and damaged area size of impervious facilities,the numerical analysis and field test methods are used.The comparison with real measurements indicates that the analysis results are correct.The conclusion of research can provide theoretical basis for leakage control.