首页> 中文期刊> 《热力发电》 >Numerical simulation based cold tests for a tangentially fired boiler

Numerical simulation based cold tests for a tangentially fired boiler

         

摘要

Such problems as flameout and serious slagging frequently occurred in a 170 t/h tangentially fired boiler burning inferior coals and with low load.Thus,cold tests were carried out to comprehensively investigate the performance of each air tube and the size and position of the tangential circle.Therefore,the cause and area of slagging in furnace can be determined.Thus,by numerical simulation on combustion,the optimal operation parameters for the boiler burning different coals under various loads conditions can be provided.The actual application showed that,the boiler fed with present coal can be long-term operated stably at 60% load,and its heat efficiency was up to 91%.Moreover,the abnormal flameout no longer occurred,and the slagging was alleviated a lot.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号