Droop control method for load share and voltage regulation in high-voltage microgrids

机译:高压微电网负荷分担和电压调节的下垂控制方法

获取原文
获取原文并翻译 | 示例
       

摘要

When the line impedance is considered in the microgrid, the accuracy of load sharing will decrease. In this paper, the impact of line impedance on the accuracy of load sharing is analyzed. A robust droop control for a highvoltage microgrid is proposed based on the signal detection on the high-voltage side of the coupling transformer. For a high-voltage microgrid, the equivalent impedance of coupling transformer connecting distributed generator with the grid is usually the dominate factor. Compared with the conventional droop control strategy, the proposed control method in this paper detects the feedback signal from the high-voltage side of the coupling transformer. The impact of line impedance on the load sharing accuracy can be mitigated significantly. The proposed droop control only changes the detection point of the feedback signal, thus it is easy to be implemented. The PSCAD/EMTDC simulation results show the effectiveness of the proposed robust droop control concept in load sharing and voltage regulation with highly accuracy.
机译:当在微电网中考虑线路阻抗时,负载共享的准确性将减小。本文分析了线路阻抗对负荷共享准确性的影响。基于耦合变压器的高压侧的信号检测提出了一种用于高压微电网的强大的下垂控制。对于高压MicroGrid,将分布式发电机与网格连接的耦合变压器的等效阻抗通常是主导因子。与传统的下垂控制策略相比,本文中所提出的控制方法检测来自耦合变压器的高压侧的反馈信号。线阻抗对负载分享精度的影响可以显着减轻。所提出的下垂控制仅改变反馈信号的检测点,因此易于实现。 PSCAD / EMTDC仿真结果表明,具有高精度的负载共用和电压调节中提出的强大的下垂控制概念的有效性。