以三联供系统建设为目标,针对不同类型公用建筑的电力负荷进行了分类、分季节、分时段的负荷分析。根据相关国家规范和设计,推导出一系列负荷分析计算方法,并计算出数据结果。与日本相关数据进行了比对,分析了偏差原因,提出更精确预测的方案和要求。%Focusing on the construction of energy supply system with three form loads, power load for different types of public buildings were analyzed from classification, season and time. In accordance with the relevant specifica- lions and design, a series of load calculation methods and data results were given. Comparison with Japan related data, the deviation cause were analyzed, the more programme and requirements were put forward accurately.