简要介绍晒谷坪电站卧式机组的结构形式和机组出现的振动情况,对机组产生振动的原因进行了分析,并针对不同的原因在实际检修中进行了针对性的处理,解决了机组的振动问题.%Abnormal vibrations are observed in the horizontal type generator units in Shaiguping Hydropower Station. With the introduction of the unit structure , reasons of these vibrations are analyzed.Treatment measures are then pro-posed and taken according to different cases.With these measures , the fault has been successfully eliminated.
展开▼