Presents the cold and heat sources system design and the control measures of this project. Adopts the ground water-source heat pump as the cold and heat sources, and provides the chilled water for the inner zone with the return water of ground water-source heat pump in winter. Reports the ground water-source heat pump design, the characteristics of chilled water system and ventilation system (including the banquet hall, guest room, and natatorium), the heat recovery system design, and the noise reduction and vibration isolation measures in detail.%介绍了承德喀喇城大酒店冷热源系统的设计和控制方法,采用地下水地源热泵系统为空调冷热源,冬季内区利用水源回水供冷.详细阐述了地下水地源热泵系统、酒店空调水系统、空调风系统(宴会厅、客房、游泳池)、集中热回收系统的设计和消声隔振措施.