首页> 中文期刊> 《流量控制、测量及可视化(英文)》 >Flow-Accelerated Corrosion in Pipe Wall Downstream of Orifice for Water and Air-Water Bubble Flows

Flow-Accelerated Corrosion in Pipe Wall Downstream of Orifice for Water and Air-Water Bubble Flows

             

摘要

An orifice is used widely as a flow meter or a contraction device in pipeline systems in hydro-power plants, thermal power plants, and chemical plants because of its simple construction, high reliability, and low cost. However, it is well known that flow-accelerated corrosion (FAC) occurs on the pipe wall downstream of the orifice. Some of the authors have examined FAC through experimental and numerical analyses and have reported that one of the major governing parameters of FAC for single-phase water flow is the pressure fluctuation p’ on the pipe wall, and also that pipe wall thinning rate TR can be estimated by p’. In addition, they have presented the effects of the ori-fice geometry on p’ or TR, and have described a method for suppressing p’ or TR. In the present study, FAC for a two-phase air-water bubble flow is examined and compared with the single-phase water flow experimentally. Further, it is shown that because p’ is also considered a governing parameter of FAC for a two-phase air-water bubble flow, TR can be estimated using p’. It is also indicated that, by using a downstream pipe with a smaller diameter than that of the upstream pipe, p’ or TR can be suppressed.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有