首页> 中文期刊> 《职业病与环境医学(英文)》 >Evaluation of Asbestos Exposure Associated with Research Laboratories

Evaluation of Asbestos Exposure Associated with Research Laboratories

         

摘要

Asbestos containing materials (ACM) have been used for decades in research laboratory products including gloves, tong sleeves, Transite board, and other materials. These materials typically contain chrysotile asbestos with concentrations ranging up to 80%. The objective of this research was to evaluate asbestos exposure from gloves, tong sleeves, and Transite board with simulated laboratory use. An environmental chamber was used to simulate laboratory application of the products. Bulk samples of various products were tested before and after use. Personal breathing zone air samples as well as one cumulative air sample were collected during testing and followed the National Institute for Occupational Safety and Health (NIOSH) 7400/7402 methodologies. Phase contrast microscopy (PCM) and transmission electron microscopy (TEM) were used for sample analyses. Analysis of air samples using PCM, showed airborne fiber concentrations as high as 0.058 f/cc during use of tongs fitted with asbestos sleeves. Further analysis using TEM showed that the highest airborne fiber concentration was 0.0036 f/cc. Manipulation of Transite board resulted in 8-hour time-weighted-average (TWA) asbestos levels as high as 0.02 f/cc. Testing of various asbestos containing materials used in research laboratories indicate low potential for asbestos fiber exposures.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信