首页> 中文期刊> 《材料科学技术:英文版》 >Evaluation of Surface Cracks Using Magnetic Flux LeakageTesting

Evaluation of Surface Cracks Using Magnetic Flux LeakageTesting

         

摘要

The magnetic field distribution characteristics of surface cracks with various widths are discussed based on finite element (FEM) results. The crack depth was 0.20 mm, the width range was from 0.02 to 1.00 mm. The results showed that crack width and lift-off (the distance between surface and sensor) will influence signals. Discussed in this paper is the influence of various lift-off parameters on the peak to peak values of the normal component in magnetic flux leakage testing. The effects can be applied to evaluate surface breaking cracks of different widths and depths.An idea is presented to smooth narrow, sharp crack tips using alternating current (AC) field magnetization.