首页> 外文期刊>中华医学杂志(英文版) >Clinical utility of automated platelet clump count in the screening for ethylene diamine tetraacetic acid-dependent pseudothrombocytopenia
【24h】

Clinical utility of automated platelet clump count in the screening for ethylene diamine tetraacetic acid-dependent pseudothrombocytopenia

机译:自动血小板聚集计数在乙二胺四乙酸依赖性假性血小板减少症筛查中的临床应用

获取原文
获取原文并翻译 | 示例
           

摘要

Background Platelet (PLF) clumping occurring in pseudothrombocytopenia (PTCP) can result in inaccurate PLT.Automated platelet clump count (APCC) is a quantitative parameter of platelet aggregation.In this study,we evaluated the clinical utility of APCC in the screening for platelet aggregation related ethylene diamine tetraacetic acid (EDTA)-dependent PTCP (EDTA-PTCP).Methods A total of 105 patients and 200 healthy individuals were enrolled in this study.Blood samples were collected with dipotassium EDTA and sodium citrate respectively.ADVIA 2120 hematology analyzer was used to perform complete blood count (CBC) and APCC.Blood smears of both EDTA- and citrate-anticoagulated samples were made for microscope observation and manual PLT counting.Results In 25 patients with EDTA-PTCP patients,for EDTA-2K anticoagulated-blood,PLT was (55±6)×109/L,significantly lower than citrate anticoagulated blood ((186±13)×109/L)).APCC was (905±694)×109/L,significantly higher than citrate anticoagulated blood (98±37)×109/L.In true thrombocytopenia and healthy control groups,APCC was (63±60)×109/L and (69±59)×109/L respectively and there was no significant difference between EDTA and citrate anticoagulants.Receiver operator characteristic (ROC) curve showed both sensitivity and specificity of APCC were 96% when the cutoff value of APCC was set as 182×109/L.Other platelet parameters had poor performance.Conclusion The APCC has a good sensitivity and specificity in differentiating EDTA-PTCP from true thrombocytopenia compared with other platelet parameters.
机译:背景血小板(PLF)在假性血小板减少症(PTCP)中结块可能会导致PLT不准确。自动血小板凝块计数(APCC)是血小板聚集的定量参数。在这项研究中,我们评估了APCC在筛选血小板聚集中的临床实用性方法选取105例患者和200例健康人作为研究对象,分别收集乙二胺四乙酸(EDTA)依赖的PTCP(EDTA-PTCP),分别用EDTA钾和柠檬酸钠收集血液样本,使用ADVIA 2120血液分析仪结果:25例EDTA-PTCP患者中,EDTA-2K抗凝血用于EDTA-2K抗凝血,用于EDTA和柠檬酸盐抗凝样品的血液涂片检查,以进行显微镜观察和人工PLT计数。 ,PLT为(55±6)×109 / L,显着低于柠檬酸盐抗凝血((186±13)×109 / L)。APCC为(905±694)×109 / L,显着高于柠檬酸盐抗凝b血脂(98±37)×109 / L。在真正的血小板减少症和健康对照组中,APCC分别为(63±60)×109 / L和(69±59)×109 / L,EDTA和EDTA之间无显着差异。 ROC曲线显示,当APCC的临界值设为182×109 / L时,APCC的敏感性和特异性均为96%。其他血小板参数的性能较差。结论APCC具有良好的敏感性和敏感性。与其他血小板参数相比,区分EDTA-PTCP与真正的血小板减少症的特异性。

著录项

  • 来源
    《中华医学杂志(英文版)》 |2011年第20期|3353-3357|共5页
  • 作者单位

    Department of Laboratory, Peking Union Medical College Hospital and Chinese Academy of Medical Sciences, Beijing 100730, China;

    Department of Laboratory, Peking Union Medical College Hospital and Chinese Academy of Medical Sciences, Beijing 100730, China;

    Department of Laboratory, Peking Union Medical College Hospital and Chinese Academy of Medical Sciences, Beijing 100730, China;

    Department of Laboratory, Peking Union Medical College Hospital and Chinese Academy of Medical Sciences, Beijing 100730, China;

    Department of Laboratory, Peking Union Medical College Hospital and Chinese Academy of Medical Sciences, Beijing 100730, China;

    Department of Laboratory, Peking Union Medical College Hospital and Chinese Academy of Medical Sciences, Beijing 100730, China;

  • 收录信息 中国科学引文数据库(CSCD);中国科技论文与引文数据库(CSTPCD);