首页> 外文期刊>中华医学杂志(英文版) >Relationship between 6-minute walk test and pulmonary function test in stable chronic obstructive pulmonary disease with different severities
【24h】

Relationship between 6-minute walk test and pulmonary function test in stable chronic obstructive pulmonary disease with different severities

机译:严重程度不同的稳定型慢性阻塞性肺疾病6分钟步行测试与肺功能测试的关系

获取原文
获取原文并翻译 | 示例
           

摘要

Background The relationship between the 6-minute walk test (6MWT) and pulmonary function test in stable chronic obstructive pulmonary disease (COPD) remains unclear.We evaluate the correlation of 6MWT and spirometric parameters in stable COPD with different severities.6MWT data assessed included three variables:the 6-minute walk distance (6MWD),6-minute walk work (6MWORK),and pulse oxygen desaturation rate (SPO2%).Methods 6MWT and pulmonary function test were assessed for 150 stable COPD patients with different severities.Means and standard deviations were calculated for the variables of interest.Analysis of variance was performed to compare means.Correlation coefficients were calculated for 6MWT data with the spirometric parameters and dyspnea Borg scale.Multiple stepwise regression analysis was used to screen pulmonary function-related predictors of 6MWT data.Results The three variables of 6MWT all varied as the severities of the disease.The 6MWD and 6MWORK both correlated with some spirometric parameters (positive or negative correlation; the absolute value of r ranging from 0.34 to 0.67; P<0.05) in severe and very severe patients,and the SPO2% correlated with the dyspnea Borg scale in four severities (r=-0.33,-0.34,-0.39,-0.53 respectively; P <0.05).The 6MWD was correlated with the 6MWORK in four severities (r=0.56,0.57,0.72,0.81 respectively,P <0.05),and neither of them correlated with the SPO2%.The percent of predicted forced expiratory volume in 1 second (FEV1% predicted) and residual volume to total lung capacity ratio (RV/TLC) were predictors of the 6MWD,and the maximum voluntary ventilation (MW) was the predictor of the 6MWORK.Conclusions 6MWT correlated with the spirometric parameters in severe and very severe COPD patients.6MWT may be used to monitor changes of pulmonary function in these patients.
机译:背景稳定慢性阻塞性肺疾病(COPD)的6分钟步行测试(6MWT)与肺功能测试之间的关系尚不清楚。我们评估了不同严重程度的稳定COPD患者6MWT和肺活量参数之间的相关性。评估的6MWT数据包括三个变量:6分钟步行距离(6MWD),6分钟步行工作(6MWORK)和脉搏氧去饱和率(SPO2%)。方法采用6MWT和肺功能测试方法对150名不同严重程度的稳定COPD患者进行评估。计算感兴趣变量的标准差;进行方差分析以比较均值;计算6MWT数据与肺活量参数和呼吸困难Borg量表的相关系数;采用多元逐步回归分析筛选与6MWT相关的肺功能相关指标数据。结果6MWT的三个变量随疾病的严重程度而变化。6MWD和6MWORK均与某些疾病相关肺活量参数(正或负相关; r的绝对值在0.34至0.67之间;重度和极重度患者的PPO <0.05,SPO2%与呼吸困难的Borg量表在四个严重程度(r = -0.33,-0.34,-0.39,-0.53; P <0.05)相关。6MWD与6MWORK在4种严重度下(分别为r = 0.56、0.57、0.72、0.81,P <0.05),均与SPO2%无相关性。1秒内预测的强制呼气量百分比(FEV1%预测值)和残余量肺总容量比(RV / TLC)是6MWD的预测指标,最大自愿通气(MW)是6MWORK的预测指标。结论6MWT与重度和非常重度COPD患者的肺活量参数相关。可使用6MWT监测这些患者的肺功能变化。

著录项

  • 来源
    《中华医学杂志(英文版)》 |2012年第17期|3053-3058|共6页
  • 作者单位

    Department of Respiratory Medicine,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,China;

    Department of Respiratory Medicine,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,China;

    Department of Respiratory Medicine,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,China;

    Department of Respiratory Medicine,Second People's Hospital of Chengdu,Chengdu,Sichuan 610017,China;

    Department of Respiratory Medicine,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,China;

    Department of Respiratory Medicine,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,China;

    Department of Respiratory Medicine,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,China;

    Department of Respiratory Medicine,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,China;

  • 收录信息 中国科学引文数据库(CSCD);中国科技论文与引文数据库(CSTPCD);
  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号