Background:Recrossing the compromised side branch (SB) with a balloon is sometimes technically challenging.The aim of this study was to evaluate whether in-stent anchoring (ISA) is safe and effective to facilitate SB balloon delivery for final kissing.Methods:One hundred and fifty-nine consecutive patients were included (166 bifurcation lesions) in this prospective,single-center registry.ISA was used as a bailout method after unsuccessful SB crossing using conventional techniques,including low-profile balloons.Technique success was defined as SB balloon delivery and final kissing.Results:Kissing-balloon delivery was successfully performed with conventional strategies in 149 of 166 lesions (89.8%).In the remaining 17 lesions (10.2%),recrossing of the main vessel stent strut was not successful;therefore,ISA was attempted.The balloon successfully crossed the stent struts,and final kissing was achieved in 15 of 17 lesions (88.2%).Total final kissing was achieved in 164 of 166 lesions (98.8%),with success rates of 100% in the single-stent group and 97.6% in the two-stent group.Two cases without balloon delivery had complex bifurcation lesions with severe calcification.There was no vessel dissection in the anchoring zone.Conclusions:ISA is safe and effective for recrossing stent struts when conventional low-profile balloons have failed.However,large-scale trials are warranted for further evaluation.
机译:背景:用气球将受损的侧枝(SB)交叉有时在技术上具有挑战性。本研究的目的是评估支架内锚固(ISA)是否安全有效地促进SB气球的最终吻合。该前瞻性,单中心登记处包括159例患者(166个分叉病变)。使用常规技术(包括低调气囊)成功通过SB后,将ISA用作救助方法。技术成功定义为SB结果:采用常规策略成功地将吻吻气球送入166个病变中的149个(占89.8%)。在其余17个病变(占10.2%)中,主血管支架撑杆未成功交叉;因此气球成功越过支架支柱,最终吻合在17个病变中的15个中占88.2%。总最终吻合在166个病变中的164个中(98.8个) %),单支架组成功率100%,双支架组成功率97.6%。两例无球囊分娩的复杂性分叉病变,钙化严重,锚固区无血管夹层。结论:当常规的低姿态球囊失效时,ISA可安全有效地重新穿过支架支撑杆。但是,仍需进行大规模试验以进行进一步评估。

著录项

  • 来源
    《中华医学杂志(英文版)》 |2016年第22期|2666-2669|共4页
  • 作者单位

    Institution of Cardiovascular Research, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;

    Institution of Cardiovascular Research, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;

    Institution of Cardiovascular Research, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;

    Department of Cardiovascular, First People's Hospital of Chongqing New North Zone, Chongqing 401120, China;

    Institution of Cardiovascular Research, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;

    Institution of Cardiovascular Research, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;

    Interventional Cardiology, San Raffaele Scientific Institute, Milan, Italy;

  • 收录信息 中国科学引文数据库(CSCD);中国科技论文与引文数据库(CSTPCD);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号