Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study

机译:使用模块化小梁金属髋臼组件进行全髋关节置换术治疗髋臼骨折失败:中期随访研究

获取原文
获取原文并翻译 | 示例
       

摘要

Background:Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures,and good results have been reported with the use of these cups;however,the durability and functionality of modular trabecular metal (TM) acetabular components in acetabular reconstruction after failed treatment of acetabular fractures remain unclear.This study aimed to examine the radiographic and clinical outcomes associated with the use of modular TM acetabular components for failed treatment of acetabular fractures to assess the durability and functionality of these components in acetabular reconstruction after failed treatment of acetabular fractures.Methods:A total of 41 patients (41 hips) underwent total hip arthroplasty (THA) using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January 2007 and December 2012.Among these patients,two were lost to follow-up.Therefore,39 patients (39 hips) were finally included in this study.The Harris hip score before and after the surgery,satisfaction level of the patients,and radiographic results were assessed.Results:The mean Harris hip score increased from 34 (range,8-52) before surgery to 91 (range,22-100) at the latest follow-up examination (P < 0.001).The results were excellent for 28 hips,good for six,fair for three,and poor for two.Among the 39 patients,25 (64%) and 10 (26%) were very satisfied and somewhat satisfied,respectively.All cups were found to be fully incorporated,and no evidence of cup migration or periacetabular osteolysis was noted.Conclusions:Despite the technically demanding nature of the procedure,THA using modular TM acetabular components showed good durability and functionality and may be an effective reconstruction option for failed treatment of acetabular fractures.
机译:背景:多孔涂层杯在髋臼骨折治疗失败后已广泛用于髋臼重建,并已报道使用这些杯具良好效果;但是,模块化小梁金属(TM)髋臼组件在髋臼中的耐用性和功能性髋臼骨折治疗失败后的重建仍不清楚。本研究旨在检查与使用模块化TM髋臼组件治疗髋臼骨折有关的放射学和临床结果,以评估这些组件在髋臼骨折治疗后的耐用性和功能性方法:2007年1月至2012年12月,共41例患者(41髋)采用模块化TM髋臼组件进行全髋关节置换术(THA),治疗髋臼骨折失败。其中2例失访因此,最终有39例患者(39髋)评估手术前后的哈里斯髋关节评分,患者满意度和影像学检查结果。结果:平均哈里斯髋关节评分从手术前的34(范围:8-52)增加到91(范围) ,22-100)在最新的随访检查中(P <0.001)。结果好于28髋,好6例,一般3例,差2例。在39例患者中,25例(64%)和10名(26%)分别表示非常满意和某种程度的满意。发现所有杯子均已完全合并,没有发现任何杯子移位或髋臼周围骨溶解的证据。结论:尽管手术技术要求高,使用模块化TM的THA髋臼组件显示出良好的耐用性和功能性,可能是髋臼骨折治疗失败的有效重建选择。

著录项

  • 来源
    《中华医学杂志(英文版)》 |2016年第8期|903-908|共6页
  • 作者单位

    Department of Orthopedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing 100035, China;

    Department of Orthopedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing 100035, China;

    Department of Orthopedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing 100035, China;

    Department of Orthopedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing 100035, China;

    Department of Orthopedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing 100035, China;

    Department of Orthopedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing 100035, China;

  • 收录信息 中国科学引文数据库(CSCD);中国科技论文与引文数据库(CSTPCD);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-19 03:58:52
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号