首页> 中文期刊>中华创伤杂志 >喙锁螺钉与双Endobutton钢板治疗肩锁关节脱位的临床研究

喙锁螺钉与双Endobutton钢板治疗肩锁关节脱位的临床研究

摘要

Objective To evaluate and compare the clinical outcome of coracoclavicular screw and double Endobutton plate in treatment of acromioclavicular dislocation ( Rockwood Ⅲ-Ⅴ ). Methods Twenty-eight patients with Rockwood Ⅲ-Ⅴ acromioclavicular dislocation were subjected to surgical reconstruction from January 2008 to October 2009. The coracoclavicular screw was performed in 14 patients and the double Endobutton plate in the other 14 patients. Clinical evaluation was performed by using Constant score and subject should value (SSV) in both groups, and the preoperative and postoperative radiographs, curative effects and complications were compared. Results The patients in two groups were followed up for a range of 6-25 months (average 12.6 months) , which showed higher postoperative Constant score and SSV score than preoperation in both groups (P<0.05). But the postoperative Constant sore and postoperative SSV score in the double Endobutton group were (89.8 ±8.3) points and (85.7 ±7. 3) points respectively, significantly better than (78. 0 ± 10. 3) points and (71. 8 ±9. 7) points respectively in the coracoclavicular screw group ( P < 0.05). The radiologic measurement showed no significant difference in regard of the coracoclavicular distance three months after operation in two groups (P>0.05). Conclusions The double Endobutton plate can attain significantly superior clinical outcomes for Rockwood Ⅲ-Ⅴ acromioclavicular dislocation compared with the coracoclavicular screw. The surgical technique of reconstructing the coracoclavicular ligament through anatomical approach will be the future trend in treatment of the acromioclavicular joint dislocation.%目的 探讨喙锁螺钉与双Endobutton钢板治疗Rockwocd Ⅲ~Ⅴ型肩锁关节脱位的临床疗效,并对两者进行对比研究.方法自2008年1月至2009年10月收治Rockwood Ⅲ~Ⅴ型肩锁关节脱位患者28例,电脑随机抽样分为两组,14例采用喙锁螺钉治疗,另14例采用双Endobutton钢板治疗.采用Constant评分和自我评分系统(subject should value,SSV)评价肩关节功能,并对两组临床疗效、影像学结果及并发症进行对比研究.结果两组患者术后均获6~25个月随访,平均12.6个月,术后Constant评分和SSV评分均优于术前(P<0.05),但术后Constant评分和SSV评分双Endobutton钢板组分别以(89.8±8.3)分、(85.7±7.3)分明显优于喙锁螺钉组的(78.0 ±10.3)分、(71.8±9.7)分(P<0.05),术后3个月两组影像学测量差异无统计学意义(P>0.05).结论 双Endobutton钢板治疗Rockwood Ⅲ~Ⅴ型肩锁关节脱位的临床疗效优于喙锁螺钉治疗,其通过解剖方式重建喙锁韧带将成为治疗肩锁关节脱位的未来发展趋势.

著录项

  • 来源
    《中华创伤杂志》|2011年第7期|598-603|共6页
  • 作者单位

    325027,温州医学院附属第二医院骨科;

    325027,温州医学院附属第二医院骨科;

    325027,温州医学院附属第二医院骨科;

    325027,温州医学院附属第二医院骨科;

    325027,温州医学院附属第二医院骨科;

    325027,温州医学院附属第二医院骨科;

    325027,温州医学院附属第二医院骨科;

    325027,温州医学院附属第二医院骨科;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    肩锁关节; 脱位; 骨板; 对比研究;

  • 入库时间 2023-07-25 11:20:25

相似文献

  • 中文文献
  • 外文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号