The welded joint of dissimilar heat-resisting steels 20Crl2MoV(F12)and 12 Cr2MoWVTiB(102)generally works around 600°C.In this paperthree kinds of ferritic electrodes are used for testing.They are R817 high-strength electrode(CrllMoVNi),R347 low-strength electrode(Cr2MoVWB)and newly-developed R507MoNb medium-strength electrode.The study on theinfluence of those three different electrodes on carbon migration,HIC and hy-drogen diffusion shows that medium-strength electrodes can well control thecarbon migration,and that the tendency to HIC in the joint formed by R817 issmaller than that by R347 instead.Considering the effect of weld metal transfor-mation on the restraint stress and hydrogen concentration of a joint,the hydro-gen distribution in the heat-affected zone(HAZ)is calculated by using finite ele-ment method(FEM)with stress and strain changing,and so the effect of thetransformation behaviour on HIC is revealed.In addition,newly-developedR507MoNb electrodes,tested the elevated-temperature property,oxidation re-sistance and creep rupture strength,have fulfilled the technical standards con-cerned and passed the examination of on-the-spot operation.