针对CO2压缩机二段段间冷却器E-119泄漏的原因进行了分析,采取了堵管处理,新增1台U形换热器E-119B,并加强对E-119和E-119B的监控等措施,结果表明:E-119已不泄漏。%The analysis of the reason of leakaging on second stage cooler E-119 of carbon dioxide compressor was made, treatment measure of tube plugging was adopted, one U-shaped heater E-119B was newly added, and supervision measure etc.was strengthened for E-119 and E-119B.Result indi-cates that no leakage exists for the E-119 .