首页> 外文学位 >Calibration of the OSU psychrometric chamber and first experiments.
【24h】

Calibration of the OSU psychrometric chamber and first experiments.

机译:OSU干燥室的校准和首次实验。

获取原文
获取原文并翻译 | 示例

摘要

Scope and method of study. Complete the construction of a new psychrometric chamber at OSU and demonstrate that the chamber is capable of performing accurate and precise experiments on thermal systems with and without a live thermal load.;Findings and conclusions. Completion of the chamber involved the development and fabrication of the control system. The control system included both the hardware and software needed to adjust and maintain the conditions in both the indoor and outdoor rooms. After completing the control system the chamber was ran in order to produce conditions needed to perform two experiments. These two experiments include the testing of an 11-ton (39 kW) rooftop air-conditioning unit and the establishment of thermal conductivity for different cold pipe insulation systems exposed to both moist air condensing and non-condensing conditions. Not only was these experiments performed but, the required experimental setup was also design and construct for both. An uncertainty analysis was performed on these setups and it shows to produce excellent theoretical uncertainty. The actual experiments results and accuracies confirm these finding as well as the experimental setups designs, fabrications, and abilities. Furthermore, the validation of the chamber and chamber control system was proven proficient at performing these two different experiments. These two experiments were different in nature; in both experiments a range of conditions were used, further validating the chamber and control system's capabilities.
机译:研究范围和方法。在OSU完成新的湿度计箱的建设,并证明该计箱能够在有热负荷和无热负荷的情况下在热系统上执行准确而精确的实验。;发现和结论。腔室的完成涉及控制系统的开发和制造。控制系统包括调整和维护室内和室外房间条件所需的硬件和软件。完成控制系统后,运行该腔室以产生执行两个实验所需的条件。这两个实验包括对11吨(39千瓦)屋顶空调设备的测试,以及在暴露于潮湿空气冷凝和非冷凝条件下的不同冷管绝热系统的导热系数的确定。不仅进行了这些实验,而且还为两者设计和构造了所需的实验装置。在这些设置上进行了不确定性分析,显示出极好的理论不确定性。实际的实验结果和准确性证实了这些发现以及实验装置的设计,制造和能力。此外,腔室和腔室控制系统的验证被证明可以熟练地执行这两个不同的实验。这两个实验本质上是不同的。在两个实验中,都使用了一系列条件,进一步验证了腔室和控制系统的功能。

著录项

  • 作者

    Worthington, Kasey.;

  • 作者单位

    Oklahoma State University.;

  • 授予单位 Oklahoma State University.;
  • 学科 Engineering Mechanical.
  • 学位 M.S.
  • 年度 2011
  • 页码 125 p.
  • 总页数 125
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号