Digital imaging and the Vic-3D program were used to measure deformations during a displacement controlled cyclic triaxial test of a clay specimen confined by vacuum. Seven stages of testing, each of 50 cycles, were completed. Imaging and LVDT measurements were compared. Additionally, measurements from specimen and membrane markings were compared.; Measurements from an LVDT and the Vic-3D image correlation program were compared using a direct comparison of strains with estimated error bands and a statistical test of coincidence of resilient modulus regression curves. The Vic-3D program successfully replicated LVDT results. Both total and plastic strains exhibited similar trends and magnitudes. Resilient modulus curves were statistically coincident at the 99% confidence level.; Digital image correlation provides the advantages of field measurements, allowing the identification and measurement of the area with the most uniform strain field. The dummy variable model and the F test for coincidence offer a quantitative method for comparing any number of regression curves.; Two sample t-tests compared side by side subsets of different marking techniques in the top, middle, and bottom thirds of the specimen. Vertical deformations based on specimen markings were statistically equal to those based on membrane markings for the top and middle thirds of the specimen at overall strain values of less than 10%. Axial strains and radial deformations based on the two marking techniques were not statistical equal. There were indications that the background applied to the specimen affected pore water drainage. Further inquiry is needed to establish the ideal marking technique.; The research raised the question of whether the precision of the imaging measurements and the statistical analysis exceeds the precision of the test method. For example, in one stage, all plastic deformations were within 0.018 mm (0.0007 in.) but were not statistically equal.; Vic-3D offered insight into the effects of data smoothing on strain calculations. Using a high degree of smoothing, strain data was shown to parallel findings of previous researchers. At lesser levels of smoothing, the same data set contradicted previously reported results. More study is needed to establish the proper degree of smoothing for various measurement applications.
机译:使用数字成像和Vic-3D程序来测量由真空限制的黏土样品在位移控制的循环三轴测试过程中的变形。完成了七个测试阶段,每个阶段有50个循环。比较了成像和LVDT测量。另外,比较了从标本和膜标记的测量值。使用直接比较具有估计误差带的应变以及对弹性模量回归曲线的一致性进行统计检验,比较了LVDT和Vic-3D图像相关程序的测量结果。 Vic-3D程序成功复制了LVDT结果。总应变和塑性应变都显示出相似的趋势和大小。弹性模量曲线在99%的置信度水平上统计重合。数字图像关联提供了现场测量的优势,可以识别和测量具有最均匀应变场的区域。虚拟变量模型和一致性的F检验为比较任意数量的回归曲线提供了一种定量方法。两次样本t检验比较了样本顶部,中部和底部三分之一中不同标记技术的并排子集。在总应变值小于10%时,基于样本标记的垂直变形在统计学上等于基于样本顶部和中间三分之一的薄膜标记的垂直变形。基于两种标记技术的轴向应变和径向变形在统计上不相等。有迹象表明,施加到样本的背景影响孔隙水的排出。需要进一步询问以建立理想的标记技术。研究提出了成像测量和统计分析的精度是否超过测试方法的精度的问题。例如,在一个阶段中,所有塑性变形都在0.018毫米(0.0007英寸)以内,但在统计学上不相等。 Vic-3D提供了有关数据平滑对应变计算的影响的见解。使用高度的平滑度,应变数据显示为先前研究人员的平行发现。在较小的平滑度下,相同的数据集与先前报告的结果相矛盾。需要进行更多的研究才能为各种测量应用建立适当的平滑度。

著录项

  • 作者

    Montemayor, Eleazar.;

  • 作者单位

    University of South Carolina.;

  • 授予单位 University of South Carolina.;
  • 学科 Engineering Civil.
  • 学位 Ph.D.
  • 年度 2003
  • 页码 159 p.
  • 总页数 159
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 建筑科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号