首页> 外文学位 >Investigation of potential factors affecting the measurement of dew point temperature in oil-soaked transformers.
【24h】

Investigation of potential factors affecting the measurement of dew point temperature in oil-soaked transformers.

机译:研究影响浸油变压器露点温度测量的潜在因素。

获取原文
获取原文并翻译 | 示例

摘要

Moisture within a transformer's insulation system has been proven to degrade its dielectric strength. When installing a transformer in situ, one method used to calculate the moisture content of the transformer insulation is to measure the dew point temperature of the internal gas volume of the transformer tank. There are two instruments commercially available that are designed for dew point temperature measurement: the Alnor Model 7000 Dewpointer and the Vaisala DRYCAPRTM Hand-Held Dewpoint Meter DM70. Although these instruments perform an identical task, the design technology behind each instrument is vastly different.;When the Alnor Dewpointer and Vaisala DM70 instruments are used to measure the dew point of the internal gas volume simultaneously from a pressurized transformer, their differences in dew point measurement have been observed to vary as much as 30 °F. There is minimal scientific research available that focuses on the process of measuring dew point of a gas inside a pressurized transformer, let alone this observed phenomenon.;The primary objective of this work was to determine what effect certain factors potentially have on dew point measurements of a transformer's internal gas volume, in hopes of understanding the root cause of this phenomenon. Three factors that were studied include (1) human error, (2) the use of calibrated and out-of-calibration instruments, and (3) the presence of oil vapor gases in the dry air sample, and their subsequent effects on the Q-value of the sampled gas. After completing this portion of testing, none of the selected variables proved to be a direct cause of the observed discrepancies between the two instruments.;The secondary objective was to validate the accuracy of each instrument as compared to its respective published range by testing against a known dew point temperature produced by a humidity generator. In a select operating range of -22 °F to -4 °F, both instruments were found to be accurate and within their specified tolerances. This temperature range is frequently encountered in oil-soaked transformers, and demonstrates that both instruments can measure accurately over a limited, yet common, range despite their different design methodologies.;It is clear that there is another unknown factor present in oil-soaked transformers that is causing the observed discrepancy between these instruments. Future work will include testing on newly manufactured or rewound transformers in order to investigate other variables that could be causing this discrepancy.
机译:事实证明,变压器绝缘系统中的水分会降低其介电强度。在现场安装变压器时,一种用于计算变压器绝缘层水分含量的方法是测量变压器箱内气体体积的露点温度。市场上有两种专门设计用于露点温度测量的仪器:Alnor 7000型露点仪和Vaisala DRYCAPRTM手持式露点仪DM70。尽管这些仪器执行相同的任务,但是每种仪器背后的设计技术都大不相同。;当使用Alnor露点仪和Vaisala DM70仪器同时测量加压变压器内部气体体积的露点时,它们在露点上的差异据观察,测量值的变化高达30°F。很少有科学研究集中在测量加压变压器内气体露点的过程上,更不用说观察到的现象了。这项工作的主要目的是确定某些因素可能对测量露点的影响。变压器的内部气体量,希望了解这种现象的根本原因。研究了三个因素:(1)人为错误;(2)使用已校准和未校准的仪器;(3)干燥空气样品中油蒸气的存在及其对质量的后续影响-采样气体的值。完成这部分测试后,没有一个选择的变量被证明是这两个仪器之间观察到差异的直接原因;第二个目标是通过对一个仪器进行测试来验证每个仪器与其各自发布范围的准确性湿度发生器产生的已知露点温度。在-22°F至-4°F的选定工作范围内,发现这两种仪器都是准确的,并且在其指定的公差范围内。这个温度范围在浸油变压器中经常遇到,并且表明尽管它们的设计方法不同,但两种仪器都可以在有限但通用的范围内进行准确的测量;很明显,浸油变压器中存在另一个未知因素导致观察到的这些工具之间的差异。未来的工作将包括对新制造或重新绕制的变压器进行测试,以调查可能导致这种差异的其他变量。

著录项

  • 作者

    Kraus, Adam H.;

  • 作者单位

    State University of New York at Buffalo.;

  • 授予单位 State University of New York at Buffalo.;
  • 学科 Engineering Electronics and Electrical.;Energy.
  • 学位 M.S.
  • 年度 2012
  • 页码 83 p.
  • 总页数 83
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词