首页> 外文学位 >A new perspective on the tensile strength of lap splices in reinforced concrete members.
【24h】

A new perspective on the tensile strength of lap splices in reinforced concrete members.

机译:钢筋混凝土构件搭接接头抗拉强度的新观点。

获取原文
获取原文并翻译 | 示例

摘要

Current U.S. design provisions for lap splices of deformed bars in tension were developed primarily from tests conducted on beams with lap lengths not exceeding 40 bar diameters. But the provisions often require splices to be longer than 40 bar diameters. Recent structural failures have indicated the vulnerability of lap splices with length-to-bar-diameter ratios equal to or exceeding 40. In this study, the tensile strength of unconfined deformed-bar lap splices with different lengths is reexamined. The focus is on lap splices with length-to-bar-diameter ratios of 40 or more. The tensile strength of lap splices in configurations resembling those observed to have splice failures in the field is also examined.;Three series of tests (with a total of forty-five specimens) were conducted on specimens with lap lengths varying from 20 to 85 bar diameters. In series one, twenty-seven prismatic coupons were tested monotonically to failure in tension. In the second and third series, a total of eighteen beams were tested to failure. The beam lap splices were located in a region of constant moment.;The results in this study indicated that increasing the length of a lap splice beyond 45 bar diameters was an inefficient way to increase the strength of the splice. The results also indicated that a mean unit bond strength of 5√f'c (in psi) is not a lower bound, as suggested by current design provisions, to the strength of unconfined deformed-bar lap splices with a minimum clear cover of 1 bar diameter and a minimum clear spacing between bars of 2 bar diameters.;To address these issues, a new perspective on the tensile strength of unconfined lap splices is explored. It is suggested that, rather than setting a lower bound to the mean unit bond strength for design, an upper bound of 900√f'c (in psi) should be set for the maximum steel stress that can be developed in unconfined deformed-bar lap splices.
机译:美国目前对拉力变形钢筋搭接部的设计规定主要是根据对搭接长度不超过40巴直径的梁进行的试验得出的。但是规定通常要求接头的直径大于40 bar。最近的结构故障表明,长度与钢筋直径之比等于或超过40的搭接接头很容易受到损坏。在这项研究中,重新检查了不同长度的无限制变形钢筋搭接接头的拉伸强度。重点是长度与杆径比为40或更大的搭接接头。还检查了搭接接头的拉伸强度,其构造类似于在现场观察到的接头失效。;对搭接长度在20至85 bar之间变化的试样进行了三组测试(共45个样品)直径。在第一个系列中,对二十七个棱形试样进行了单调拉伸测试。在第二和第三系列中,总共测试了18根光束,直至失效。梁搭接接头位于恒定力矩区域。本研究结果表明,将搭接接头的长度增加到超过45 bar的直径是提高接头强度的无效方法。结果还表明,按照当前设计规定的建议,平均单位粘结强度为5√f'c(以psi为单位)并不是下限,其最小透明覆盖层为1时,是无侧限变形钢筋搭接接头的强度的下限。钢筋直径和2钢筋直径的钢筋之间的最小净间距。;为解决这些问题,人们探索了一种新的观点,即无约束搭接的抗拉强度。建议不要为设计的平均单位粘结强度设置下限,而应为可在无限制变形钢筋中产生的最大钢应力设置上限900√f'c(以psi为单位)。搭接。

著录项

  • 作者

    Richter, Brian P.;

  • 作者单位

    Purdue University.;

  • 授予单位 Purdue University.;
  • 学科 Engineering Civil.
  • 学位 M.S.C.E.
  • 年度 2012
  • 页码 187 p.
  • 总页数 187
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号