首页> 外文会议>World conference on earthquake engineering;WCEE >RION-ANTIRION BRIDGE: DESIGN AND FULL-SCALE TESTINGOF THE SEISMIC PROTECTION DEVICES
【24h】

RION-ANTIRION BRIDGE: DESIGN AND FULL-SCALE TESTINGOF THE SEISMIC PROTECTION DEVICES

机译:RION-ANTIRION桥:防震设​​备的设计和全面测试

获取原文

摘要

The Rion-Antirion Bridge, that crosses the homonymous strait in Greece, is located in a very activeseismic region. The deck of this multi-span cable-stayed bridge is continuous and fully suspended fromfour pylons (total length of 2252 meters). Its approach viaducts comprise 228m of concrete deck on theAntirion side and 986m of steel composite deck on the Rion side. Said structures are designed towithstand seismic events generating ground accelerations of up to 0.48g through the use of fluid viscousdampers and other seismic devices.The Main Bridge seismic protection system comprises fuse restraints and viscous dampers of dimensionsheretofore never built. The same act in parallel, connecting the deck to the pylons. The restrainers aredesigned as a rigid link intended to withstand high wind loads up to a pre-determined force. Under theaction of the design earthquake, fuse restrainers will fail and leave the dampers free to dissipate theearthquake-induced energy acting upon the structure. The Approach Viaducts are seismically isolatedutilizing elastomeric isolators and viscous dampers.This paper aims to describe the aforesaid seismic protection systems as well as the results of the extensivefull-scale testing they underwent to verify design assumptions. The Damper Prototype tests wereperformed at the of the University of San Diego California Laboratory (USA), while the Fuse Restraintstest and all production tests were carried out at the FIP Industriale Testing Laboratory in Italy.
机译:穿越希腊同音海峡的里昂-安提翁桥位于地震活跃的地区。这座多跨度斜拉桥的桥面是连续的,并完全悬挂在四个塔架上(总长度为2252米)。它的引道高架桥包括在Antirion侧的228m混凝土面板和在Rion侧的986m的钢复合面板。所述结构经设计以承受地震事件,通过使用流体粘性阻尼器和其他地震装置产生高达0.48g的地面加速度。主桥地震保护系统包括迄今从未建造的尺寸的保险丝约束装置和粘性阻尼器。并行执行相同操作,将甲板连接到塔架。限制器设计为刚性链节,旨在承受高达预定力的高风荷载。在设计地震的作用下,保险丝限制器将失效,并使阻尼器自由散发作用在结构上的地震感应能量。途径高架桥是利用弹性隔离器和粘性阻尼器进行地震隔离的。本文旨在描述上述地震保护系统以及为验证设计假设而进行的全面测试的结果。阻尼器原型测试在美国加利福尼亚州圣地亚哥大学的实验室进行,而保险丝约束测试和所有生产测试均在意大利的FIP工业测试实验室进行。

著录项

  • 来源
  • 会议地点 Vancouver(CA);Vancouver(CA)
  • 作者单位

    R. & D. Dept. FIP Industriale Selvazzano Dentro Italy infanti.fip@fip-group.it;

    Kinopraxia Gefyra Antirio Aetolocarnania Greece ppapanikolas@gefyra.com;

    University of California San Diego La Jolla-California USA gbenzoni@ucsd.edu;

    R.&D. Dept. FIP Industriale Selvazzano Dentro Italy castellano.fip@fip-group.it;

  • 会议组织
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号