首页> 外文会议>Workshop on Communication Networks and Power Systems >Using current traveling waves to implement directional elements in parallel lines
【24h】

Using current traveling waves to implement directional elements in parallel lines

机译:使用当前行波在平行线中实现方向性元素

获取原文

摘要

A traveling wave-based directional element based on only current signals for parallel transmission lines is presented in this paper. With the current waveform samples captured in one-terminal of both parallel circuits, the direction of the first fault-induced traveling waves is identified. Therefore, by using two directional elements, one at each transmission line end, and applying a permissive overreaching transfer trip scheme through a communication channel in conjunction with an appropriate overcurrent supervision, it is possible to classify faults as internal or external from the monitored transmission line, without the need to analyze voltage traveling waves. This classification (internal and external) and fault direction identification (forward or reverse) can improve the performance of other protection schemes and accelerate the trip decision without compromising the protection security and reliability.
机译:本文提出了一种仅基于电流信号的并行传输线行波定向元件。利用在两个并联电路的一个端子中捕获的电流波形样本,可以识别出第一条故障引起的行波的方向。因此,通过使用两个方向性元素,在每个传输线末端使用一个方向性元素,并通过通信通道结合适当的过电流监控来应用允许的超限传输跳闸方案,可以将故障分类为受监控传输线的内部故障还是外部故障,无需分析电压行波。这种分类(内部和外部)和故障方向识别(正向或反向)可以提高其他保护方案的性能,并加速跳闸决策,而不会影响保护的安全性和可靠性。