摘要

An investigation was conducted to compare two approaches for water sampling andrntwo analytical methods for THM determination in drinking water. Results of thisrnstudy showed that the sampling protocol is critical for accurate THM determination.rnSamples collected for THM analysis should be adjusted to pH 4.5 or lower at therntime of sampling to preserve stability of trihalomethanes. More THMs were formedrnafter sampling in non pH-adjusted samples. The differences were more significantrnfor samples collected at the plant than in the distribution system. The analyticalrnmethod (liquid-liquid extraction or Purge and Trap) did not affect the quantificationrnof THMs in pH-adjusted samples. This study reinforces the need for standardisationrnof sampling protocols to prevent inaccurate determination of THMs and otherrndisinfection by-products in drinking water.
机译:进行了一项调查,以比较两种水采样方法和两种饮用水中THM测定的分析方法。研究结果表明,采样方案对于准确测定THM至关重要。为了进行三卤甲烷分析,采集的样品在采样时应将pH值调节至4.5或更低,以保持三卤甲烷的稳定性。在未经pH调整的样品中取样后,会形成更多的THM。对于工厂收集的样品,其差异比在分配系统中的差异更大。分析方法(液-液萃取或吹扫捕集)不影响pH值调节样品中THM的定量。这项研究加强了对标准化采样方案的需要,以防止饮用水中THM和其他消毒副产物的不准确测定。