首页> 外文会议>UV and Gamma-Ray Space Telescope Systems pt.1 >Chandra HRC-S Degapping Corrections
【24h】

Chandra HRC-S Degapping Corrections

机译:钱德拉HRC-S去色差校正

获取原文
获取原文并翻译 | 示例

摘要

The HRC-S is a microchannel plate detector on board Chandra and is primarily used for spectroscopic observations with the Low Energy Transmission Grating Spectrometer (LETGS) in place. Photons are detected via signals read out from evenly spaced wires underneath the plates and positions are computed by centroiding around the strongest amplifier signals. This process leads to gaps in between the taps where no events are placed. A deterministic correction is then made during ground processing to these event locations to remove the gaps. We have now developed a new, empirical degap corrections from flight data. We describe the procedure we use, present comparisons between the new degap and lab-data based degap, and investigate the temporal stability of the degap corrections.
机译:HRC-S是钱德拉(Chandra)船上的微通道板探测器,主要用于具有低能透射光栅光谱仪(LETGS)的光谱观察。通过从板下方均匀间隔的导线中读取的信号检测光子,并通过围绕最强的放大器信号进行质心来计算位置。此过程导致没有事件放置的抽头之间出现间隙。然后在地面处理期间对这些事件位置进行确定性校正,以消除间隙。现在,我们已经从飞行数据中开发了一种新的经验去像度校正。我们描述了我们使用的过程,介绍了新的degap与基于实验室数据的degap之间的比较,并研究了degap校正的时间稳定性。