This paper explores an alternative to the previous remote impedance measurement of antennas to improve the dynamic range of the needed data for the measurements. Previous work evaluated the refection coefficient of a source antenna as a function of the termination on the antenna under test (AUT). The loads used in the measurement are the classic open-short-load, with measured data used for the actual termination impedances. The impedance of the AUT is determined by a standard calibration approach. For current vector network analyzers, the dynamic range of the analog-to-digital converter limits the impedance estimate, particularly if the distance between the source and AUT is increased to reduce interaction affecting the impedance of the AUT. The new approach separates the transmit and receive functions to allow the use of a LNA to improve the receive signal strength and offer the opportunity to overcome some of the limitations of the reflection approach.
机译:本文探索了先前天线的远程阻抗测量的替代方法,以改善测量所需数据的动态范围。先前的工作评估了源天线的反射系数作为被测天线(AUT)端接的函数。测量中使用的负载是经典的开放式短负载,测量数据用于实际的终端阻抗。 AUT的阻抗通过标准校准方法确定。对于当前的矢量网络分析仪,模数转换器的动态范围会限制阻抗估计,尤其是如果增加源和AUT之间的距离以减少影响AUT阻抗的相互作用时。新方法将发送和接收功能分开,以允许使用LNA来改善接收信号强度,并提供了克服反射方法的某些限制的机会。