Concentrations of nitrogen dioxide were measured in shops and car parks over a 19 week period during the winter. For the shops indoor:outdoor ratios varied from 0.34 to 0.54 with an average value of 0.44. NO_2 levels ranged from 13 to 38 μg m~(-3). With little or no contribution from indoor sources, ambient concentrations are the primary factor in determining indoor levels. Concentrations of NO_2 in car parks were similar to those measured at the kerb side. Concentrations in the payment booths were higher than those in shops and ranged from 42 to 60 μg m~(-3). Despite ventilation systems in the payment booths ratios of boothxar park NO_2 varied from 0.65 to 0.86.
机译:在冬季的19周内对商店和停车场中的二氧化氮浓度进行了测量。对于商店,室内:室外比率从0.34到0.54不等,平均值为0.44。 NO_2含量为13〜38μgm〜(-3)。在室内来源很少或没有贡献的情况下,环境浓度是确定室内水平的主要因素。停车场中的NO_2浓度与路缘侧的浓度相似。付款亭中的浓度高于商店中的浓度,范围为42至60μgm〜(-3)。尽管支付亭中设有通风系统,但亭子公园NO_2的比率仍在0.65至0.86之间。