The effect of load tap changer (LTC) action on a transformer'snadjusted side voltage (usually the secondary side of step-downntransformers) is evaluated when the tap position on LTC is raisedn(lowered) to increase (decrease) the adjusted side voltage. The effectsnof other measures such as series and shunt compensation and theirncombination with LTCs are also evaluated. A static representation modelnof a power system model on a large populated industrial center such asnthe Puget Sound area of Bonneville Power Administration and the Bostonnarea of New England Power Service are evaluated. The characterization ofnreactive power voltage (Q-V) relation and real powernvoltage (P-V) relation curves during a voltagendegradation process is studied. The results and experience gained fromnsystem specific applications are enumerated
机译:当LTC的抽头位置升高(降低)以增加(降低)调整后的侧电压时,将评估有载分接开关(LTC)作用对变压器的调整后侧电压(通常是降压变压器的次级侧)的影响。还评估了其他措施的效果,例如串联和并联补偿以及它们与LTC的组合。对人口稠密的大型工业中心(例如Bonneville Power Administration的Puget Sound地区和New England Power Service的Bostonnarea)上的电力系统模型的静态表示模型进行了评估。无功功率电压( Q - V )关系曲线和有功功率电压( P - V )关系曲线的表征研究了电压降解过程。列举了从特定于系统的应用程序中获得的结果和经验