首页> 外文会议>Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition >Design and implementation of three-phase AC impedance measurement unit (IMU) with series and shunt injection
【24h】

Design and implementation of three-phase AC impedance measurement unit (IMU) with series and shunt injection

机译:串联和并联注入的三相交流阻抗测量单元(IMU)的设计与实现

获取原文
获取原文并翻译 | 示例

摘要

Electric power systems based on power electronics technology are prone to instability due to the constant power nature of power electronics converters. The impedances defined in synchronous coordinates are useful tools to predict and evaluate three-phase small-signal system stability. This paper presents the design and implementation of an impedance measurement unit used in three-phase systems up to 100kW. It extracts the system impedance online at any specific operating point. The unit utilizes both series and shunt injection modes to perform impedance identification for any load and source conditions, even if the source is very stiff. Experimental results demonstrate the effectiveness of the designed unit with both linear and nonlinear loads.
机译:由于电力电子转换器的恒定功率性质,基于电力电子技术的电力系统易于不稳定。同步坐标中定义的阻抗是预测和评估三相小信号系统稳定性的有用工具。本文介绍了用于功率高达100kW的三相系统中的阻抗测量单元的设计和实现。它可以在任何特定操作点在线提取系统阻抗。即使源非常坚硬,该装置也可利用串联和并联注入模式对任何负载和源条件进行阻抗识别。实验结果证明了设计的单元在线性和非线性载荷下的有效性。