首页> 外文会议>Towards the 21st century new technology and successful application of surface engineering >Failure analysis of Ti plating Pt anodes used for electrolyzing seawater in producing chlorine system
【24h】

Failure analysis of Ti plating Pt anodes used for electrolyzing seawater in producing chlorine system

机译:用于制氯系统中电解海水的钛电镀铂阳极的失效分析。

获取原文
获取原文并翻译 | 示例

摘要

The electrode specimens collected from producing chlorine system have been examined by comparative tests of electrode properties as well as eelctron probe microanalysis (EPMA),X-ray diffractioon (XRD) analysis.Results show that the damage of Ti plating Pt anode was initiated by pitting of Ti base.With electrolysis going on,Pt dissolved gradually and oxygen producted by anode reaction diffused to Ti-Pt intrface,TiO_2 was formed on surface of Ti base.The electrolyzing voltage was rising up duo to formation of oxide film,which resulted in the break of oxide film and quick corrsion (pitting) of Ti.The Ca-salt and Mg-salt and black film (TiH_2) sediment on the surface of cathode has effect on rise o eelctrolyzing voltage.
机译:通过对电极性能的对比测试以及电子探针微分析(EPMA),X射线衍射(XRD)分析对生产氯系统中收集的电极样品进行了检查。结果表明,钛镀Pt阳极的损坏是由点蚀引起的随着电解的进行,Pt逐渐溶解,阳极反应产生的氧气扩散到Ti-Pt的界面,在Ti的表面形成TiO_2,电解电压不断升高而形成氧化膜,从而形成氧化钛膜。阴极表面的钙盐,镁盐和黑膜(TiH_2)沉积物对电解电压的升高有影响。