摘要

An evaluation of the seismic isolation design of Bolu Viaduct 1 in Turkey and an assessment of its performance in the 1999 Duzce Earthquake were conducted through nonlinear finite element simulation of near-fault earthquake ground motions. The analysis indicated that the near-fault effects of ground motion at the site induced responses that exceeded the design displacements and capacities of the seismic isolation systems. This resulted in significant damage to the bearings and energy dissipation systems as observed on site. Analysis highlights the distinction between the responses of the viaduct to near-fault and far-field ground motions.
机译:通过近断层地震地震动的非线性有限元模拟,对土耳其Bolu高架桥1的隔震设计进行了评估,并评估了其在1999年Duzce地震中的性能。分析表明,现场地面运动的近断层效应引起的响应超过了地震隔离系统的设计位移和承载力。如在现场观察到的,这对轴承和能量耗散系统造成了严重损坏。分析突出了高架桥对近断层和远场地面运动的响应之间的区别。