首页> 外文会议>Therapeutics and Diagnostics in Urology: Lasers, Robotics, Minimally Invasive, and Advanced Biomedical Devices >In vivo fluorescence imaging of an orthotopic rat bladder tumor model indicates differential uptake of intravesically instilled near-infrared labeled 2-deoxyglucose analog by neoplastic urinary bladder tissues
【24h】

In vivo fluorescence imaging of an orthotopic rat bladder tumor model indicates differential uptake of intravesically instilled near-infrared labeled 2-deoxyglucose analog by neoplastic urinary bladder tissues

机译:原位大鼠膀胱肿瘤模型的体内荧光成像显示肿瘤性膀胱组织对膀胱内滴注的近红外标记的2-脱氧葡萄糖类似物的摄取差异

获取原文
获取原文并翻译 | 示例

摘要

Bladder cancer is one of the most expensive cancers to manage due to frequent recurrences requiring life-long surveillance and treatment. A near-infrared labeled 2-deoxy-d-glucose probe IRDye800CW-DG targeting glucose metabolism pathway has shown to enhance the sensitivity of diagnosing several types of cancers as tested on tumor models not including bladder tumor. This pilot study has explored differential uptake of intravesically administered IRDye800CW-DG in an orthotopic rat bladder tumor model. Twenty-five female Fischer rats were randomly grouped to four conditions: no-tumor-control (n=3), no-tumor-control intravesically instilled with IRDye800CW-DG (n=6), rats bearing GFP-labeled AY-27 rat bladder urothelial cell carcinoma cells and washed with saline (n=5), and rats bearing AY-27 tumors and intravesically instilled with IRDye800CW-DG (n=11). Near-infrared fluorescence was measured from the opened bladder wall of anesthetized rat at an excitation wavelength of 750nm and an emission wavelength of 776nm, by using an in-house fluorescence imaging system. There is no statistically significant difference of the peak fluorescence intensity among the no-tumor-control bladders (n=3), the no-tumor-control bladders instilled with IRDye800CW-DG (n=6), and the GFP-labeled AY-27 treated bladders washed by saline (n=5). When compared to that of the no-tumor-control bladders instilled with IRDye800CW-DG (n=6), the fluorescence intensity of GFP-labeled AY-27 treated bladders instilled with IRDye800CW-DG and with histology confirmed neoplastic bladder tissue (n=11) was remarkably more intense (3.34 fold of over the former) and was also statistically significant (p<0.0001). The differential uptake of IRDye800CW-DG by the neoplastic urinary bladder tissues suggests the potential for cystoscopy-adaptation to enhance diagnosis and guiding surgical management of flat urinary bladder cancer.
机译:膀胱癌是治疗最昂贵的癌症之一,因为它经常复发,需要终生监测和治疗。在不包括膀胱肿瘤的肿瘤模型上测试,靶向葡萄糖代谢途径的近红外标记的2-脱氧-d-葡萄糖探针IRDye800CW-DG已显示出增强诊断几种类型癌症的敏感性。这项初步研究探索了原位大鼠膀胱肿瘤模型中膀胱内施用IRDye800CW-DG的差异摄取。将25只雌性Fischer大鼠随机分为四个条件:无肿瘤对照(n = 3),膀胱灌注IRDye800CW-DG的无肿瘤对照(n = 6),带有GFP标记的AY-27大鼠膀胱尿路上皮细胞癌细胞并用盐水洗涤(n = 5),对患有AY-27肿瘤并经膀胱内滴注IRDye800CW-DG的大鼠(n = 11)。通过使用室内荧光成像系统,在750nm的激发波长和776nm的发射波长下,从麻醉大鼠的打开的膀胱壁中测量近红外荧光。在无肿瘤控制的膀胱(n = 3),滴注IRDye800CW-DG的无肿瘤控制膀胱(n = 6)和GFP标记的AY-之间,峰值荧光强度没有统计学上的显着差异。 27个处理过的膀胱用盐水冲洗(n = 5)。与注入IRDye800CW-DG的无肿瘤对照膀胱相比(n = 6),经GFP标记的AY-27注入IRDye800CW-DG并经组织学证实的膀胱的荧光强度证实为赘生性膀胱组织(n = 11)明显更强(是前者的3.34倍),并且在统计学上也很显着(p <0.0001)。肿瘤性膀胱组织对IRDye800CW-DG的摄取差异表明,膀胱镜适应可能增强扁平膀胱癌的诊断和指导外科治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号