首页> 外文会议>SPE western regional meeting >Development and Application of a Dual-Parameter Instrument for Steam Two Phase Flow
【24h】

Development and Application of a Dual-Parameter Instrument for Steam Two Phase Flow

机译:蒸汽两相流双参数仪表的研制与应用

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Though theoretical and experimental study, This programrncreate a method which makes use of pulsating characteristic ofrnthe water and steam two-phase flow to measure both steamrnflow rate and quality parameters. Using only a restrictionrndevice (orifice), online measures simultaneously on steamrnflow rate and quality are achieved by measuring differentrnpressure and its corresponding pulsating value.rnAccording this method, a two-phase flow instrument hasrnbeen developed, which is with simple structure and easy tornoperate. The measuring mean square errors of both flow raternand quality are less than 5% in the pressure range 2-16Mpa,rnflow rate 1-16t/h and quality 0-100%.rnThe instrument has been distributed over 430 sets in Shengli,rnXinjiang, Henan and Neimeng Erlian Oil Field.
机译:通过理论和实验研究,该程序创建了一种利用水和蒸汽两相流脉动特性来测量蒸汽流量和质量参数的方法。仅使用一个节流装置(节流孔),就可以通过测量不同的压力及其相应的脉动值来同时在线测量蒸汽的流量和质量。为此,人们开发了一种结构简单,易于成管的两相流仪表。在2-16Mpa的压力范围,1-16t / h的流速和0-100%的质量范围内,流量和质量的均方误差均小于5%。河南和内蒙古二连油田。