首页> 外文会议>Space Astronomical Telescopes and Instruments II >On-orbit management of contaminants within the Hubble Space Telescope widefield planetary camera and their effect on instrument performance
【24h】

On-orbit management of contaminants within the Hubble Space Telescope widefield planetary camera and their effect on instrument performance

机译:哈勃太空望远镜广角行星相机内部污染物的在轨管理及其对仪器性能的影响

获取原文
获取原文并翻译 | 示例

摘要

Abstract: The Wide Field Planetary Camera (WF/PC) onboard the Hubble Space Telescope contains contaminants which condense on the windows in front of each CCD detector. These contaminants are UV opaque and increase with time to the extent that after several months they block 50% of the flux at 300 nm. Also, when the contaminants are warmed above $MIN@40$DGR@C and then returned to the normal CCD operating temperature of $MIN@87$DGR@C, particles form and severely degrade the image quality. The windows may be temporarily cleaned by raising their temperature to 0$DGR@C. However, this results in a change in the structure of the flat field due to the partial removal of the UV flood which was applied after launch to suppress Quantum Efficiency Hysteresis in the CCDs. Repeated decontaminations will reintroduce the QEH and necessitate another time consuming UV flood and recalibration of the instrument. After 22 months of on-orbit operation, the contaminants could no longer be fully removed by the decontamination procedure. This paper describes the current state of the contaminants, what has been deduced concerning their properties and sources, the results of our efforts to remove them, and some lessons for future space-based instruments using cryogenic UV sensitive detectors.!2
机译:摘要:哈勃太空望远镜上的广角行星相机(WF / PC)包含污染物,这些污染物会凝结在每个CCD检测器前面的窗户上。这些污染物是紫外线不透明的,并且随着时间的增长而增加,以至于几个月后它们会阻塞300 nm处50%的通量。同样,当污染物被加热到高于$ MIN @ 40 $ DGR @ C并返回到正常CCD工作温度$ MIN @ 87 $ DGR @ C时,会形成颗粒并严重降低图像质量。可以通过将温度升至0 $ DGR @ C来暂时清洁窗户。然而,由于部分去除了在注入后被施加以抑制CCD中的量子效率滞后的UV泛光,这将导致平坦场的结构发生变化。重复的去污将重新引入QEH,并需要再次耗时的UV注入和仪器重新校准。在轨运行22个月后,去污程序无法再完全清除污染物。本文介绍了污染物的当前状态,已推断出的污染物的性质和来源,我们为去除污染物所做的努力的结果以及未来使用低温紫外线敏感探测器的天基仪器的一些经验教训。2

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号