首页> 外文会议>Society for biomaterials annual meeting and exposition >Fretting Corrosion Analysis of Ti-Mo-Zr-Fe (TMZF®) and Gas Atomized Dispersion Strengthened Co-Cr-Mo (GADS) Alloys Under Shot Peened and Shot Peened, Cleaned and Passive Conditions
【24h】

Fretting Corrosion Analysis of Ti-Mo-Zr-Fe (TMZF®) and Gas Atomized Dispersion Strengthened Co-Cr-Mo (GADS) Alloys Under Shot Peened and Shot Peened, Cleaned and Passive Conditions

机译:Ti-Mo-Zr-Fe(TMZF®)和气体雾化弥散强化Co-Cr-Mo(GADS)合金在喷丸和喷丸,清洁和钝化条件下的微动腐蚀分析

获取原文

摘要

These experiments investigated the effects of load and potential on the COF and current density during the fretting of TMZF-GADS combination with different surface treatments. In this test model, the fretting corrosion of TMZF-GADS combinations was affected by the normal load and potential and was no different from that seen for TMZF/ Co-Cr-Mo and Ti-6A1-4V/Co-Cr-Mo couples.
机译:这些实验研究了在使用不同表面处理的TMZF-GADS组合微动过程中,负载和电势对COF和电流密度的影响。在该测试模型中,TMZF-GADS组合的微动腐蚀受正常载荷和电势的影响,与TMZF / Co-Cr-Mo和Ti-6A1-4V / Co-Cr-Mo对的腐蚀无明显差异。