摘要

Many dynamic load tests have been carried out to validate the bearing capacity of pile in Japan. However, most of them are performed on the driven piles. The dynamic load test was also performed on the pile having a grouted pile toe by cement in order to improve pile capacity recently. This type of pile was used as the foundation of underground sub-way station structures and platforms. In this paper, the author presents an applicability of dynamic load test on the so-called "toe-improved pile" around H-shaped cored steel pile. A result of signal matching analysis using added-mass model for the shaft resistance on the pile clearly shows a reflection of stress waves from the pile toe and suggests that the dynamic load test will be applicable to interpret the bearing capacity of the toe-improved pile.
机译:为了验证桩的承载能力,日本进行了许多动载荷试验。但是,大多数都是在打桩机上进行的。为了提高桩的承载能力,还对具有水泥浆的桩脚的桩进行了动载荷试验。这种类型的桩用作地下地铁站的结构和平台的基础。在本文中,作者提出了在H形芯钢桩周围进行所谓的“脚趾改良桩”的动态载荷试验的适用性。使用附加质量模型对桩身上的竖井阻力进行信号匹配分析的结果清楚地显示了桩脚趾处的应力波的反射,并表明动态载荷测试将可用于解释桩脚改良桩的承载力。