The last ten years have seen the development ofrnthe self-blast technique of interruption for SF6 HVrncircuit breakers. This technique has proved to bernvery efficient and has been widely applied for highrnvoltage circuit breakers up to 800 kV. The paperrnshows the application of the same technique tornthe development of SF6 generator circuit breakersrnwith spring-operated mechanisms.rnA particular characteristic of generator circuitrnbreakers is their mandatory capability to interruptrnshort-circuit currents with delayed current zeros.rnThis requirement of ANSI/IEEE Standard C37-013rnis explained in section 3 of this paper withrnexamples of breaking tests and simulations ofrncurrent interruption.rnIn 1997 the IEEE Switchgear Committee hasrnissued a new edition of its standard C37-013 forrngenerator circuit breakers, which covers mainly thernapplications with power transformers ratedrn100MVA and above [1]. A revision of this standardrnis done by the IEEE Switchgear Committee inrnorder to extend its scope to applications of lessrnthan 100MVA rated power. This paper presentsrncalculations that have been made to calculaternTRVs for system fed faults in the case of smallrngenerator circuit breakers connected to the step-uprntransformer by cables.
机译:在过去的十年中,SF6高压断路器的自爆中断技术得到了发展。事实证明,该技术非常有效,已广泛应用于800 kV以下的高压断路器。本文显示了使用相同技术来开发带有弹簧操作机构的SF6发电机断路器的情况。发电机断路器的一个特殊特征是其具有中断电流零延迟的短路电流的强制能力.rnANSI / IEEE标准C37-013rnis的要求在本文的第3节中进行了解释,并给出了断路测试和电流中断模拟的示例。1997年,IEEE开关设备委员会发行了新版的标准C37-013发电机断路器,主要涵盖额定功率为100MVA及以上的电力变压器的应用[1]。 IEEE开关设备委员会对该标准进行了修订,以将其范围扩展到额定功率小于100MVA的应用。本文介绍了用于通过电缆将小型发电机断路器连接到升压变压器的情况下计算系统馈电故障的TRV的计算方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号