This article focuses on the ground of the space flight for star sensor product calibration and test process, the simulator pin hole size selection of strategies and evaluation methods were analyzed and discussed, With the focal length is 2000mm, caliber diameter is 200mm simulator as instance, analysis to choose the influence of different calibration precision pin hole size on the product process, through the analysis and practical verification, found that when the simulator pin hole changed from 0.06mm to 0.03mm, calibration precision products will be improved, the residual error can be reduced to a have around 0.5'.
机译:本文针对星空传感器产品标定和测试过程的航天基础,分析并讨论了模拟器针孔尺寸的选择策略和评估方法,以焦距为2000mm,口径为200mm的模拟器为例,分析选择不同的校准精度销孔尺寸对产品工艺的影响,通过分析和实际验证,发现当模拟器的销孔从0.06mm更改为0.03mm时,校准精度产品将得到改善,残留误差可以减少到大约0.5'。