Study on Automatic Isokinetic Sampling of Gas-Solid Two Phase Fluid

机译:气固两相流体自动等速采样研究

获取原文
获取原文并翻译 | 示例

摘要

The intellectual automatic isokinetic sampling system equipped with micro-computer can improve the accuracy of gas-solid two phase fluid sampling. The experiment result shows that at the fluid velocity range from 1.8m/s to 10m/s, the relative sampling velocity error is less than +- 3.5percent, that at the fluid velocity range from 5m/s to 9m/s and the fluid concentration range from 0.2kg/m~3 to 0.28kg/m~3, the relative sampling concentration error is less than +- 4.42percent. The system, applying column-shaped thermal component as its sensors for velocity, has high sensitivity and good response frequency. It can be used especially for two phase fluid at low velocity, and the result can be for engineering reference.
机译:配备微电脑的智能自动等速采样系统可以提高气固两相流体采样的准确性。实验结果表明,在流速为1.8m / s至10m / s的情况下,相对采样速度误差小于±3.5%,在流速为5m / s至9m / s的情况下,浓度范围从0.2kg / m〜3到0.28kg / m〜3,相对采样浓度误差小于±4.42%。该系统采用圆柱状热分量作为速度传感器,具有高灵敏度和良好的响应频率。特别适用于低速两相流体,其结果可作为工程参考。