The Wexner Center for the Arts went through a major facade renovation to fix the water leakage and condensation problems. The work included replacing glazed skylights, curtain walls, and roofs. This paper describes how renovation work has been done with modern technologies to study thermal and lighting performance on the new facade. In addition to the computational analysis, a full scale mock-up was constructed in a laboratory for air, water, and structural test, and to evaluate the condensation resistance performance. Currently there are no industry standards for condensation evaluation for a mock-up of this size. The mock-up test method refers to ASTM C 1199, "Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods," and AAMA 1053 test procedures but with modifications to suit the project. The new facade of the Wexner Center is a perfect example of how facade design can be done with modern analyses tools and a coordinated design approach to deliver an environmentally efficient cladding system. The paper also describes the issues for the current test standards to the projects that have specific design conditions.
机译:韦克斯纳艺术中心进行了一次大型的外墙翻新工程,以解决漏水和结露的问题。这项工作包括更换玻璃天窗,幕墙和屋顶。本文介绍了如何利用现代技术进行装修工作,以研究新立面上的散热和照明性能。除了进行计算分析外,还在实验室中针对空气,水和结构测试构建了一个完整的模型,并评估了抗冷凝性能。目前,尚无针对这种尺寸模型的冷凝评估的行业标准。样机测试方法参考ASTM C 1199,“使用热箱法测量窗框系统的稳态热透射率的标准测试方法”和AAMA 1053测试程序,但要进行修改以适合该项目。韦克斯纳中心的新立面是如何使用现代分析工具和协调设计方法完成立面设计以提供环保高效的覆层系统的完美范例。本文还介绍了针对具有特定设计条件的项目的当前测试标准的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号