首页> 外文会议>Recent research and developments in cold-formed steel design and construction >Seismic Performance of Steel Sheathed Cold-Formed steel shear walls
【24h】

Seismic Performance of Steel Sheathed Cold-Formed steel shear walls

机译:钢套冷弯型钢剪力墙的抗震性能

获取原文
获取原文并翻译 | 示例

摘要

In this paper the performance of steel sheathed cold-formed steel shear walls is evaluated by testing seven full scale walls under cyclic and monotonic loading. Of particular interest are the specimens' maximum lateral load capacity and deformation behaviour. The study also looks at the failure modes of the system and investigates the main factors contributing to the ductile response of the CFS walls in order to suggest improvements so that the steel shear walls respond plastically with a significant drift and without any risk of brittle failure, such as failure in the connections. The walls tested are of different configurations possessing different structural characteristics including: stud's thickness, width of the walls, and loading pattern. The test outcomes show that the common failure mode of the walls is an undesirable anchorage failure. Considering that there are very few criteria in the code which clarify the design of anchorage for steel sheathed systems, the study signifies the need and the importance of further research in this area.
机译:本文通过在循环和单调荷载下测试七个全尺寸墙来评估钢套冷弯型钢剪力墙的性能。样品的最大侧向承载能力和变形行为特别受关注。该研究还研究了系统的失效模式,并研究了导致CFS壁延性响应的主要因素,以提出改进建议,使钢制剪力墙塑性响应具有明显的漂移,而没有任何脆性破坏的风险,例如连接失败。所测试的墙具有不同的结构,具有不同的结构特征,包括:螺柱的厚度,墙的宽度和加载方式。测试结果表明,墙的常见破坏模式是不希望的锚固破坏。考虑到规范中很少有标准可以阐明钢护套系统的锚固设计,因此该研究表明了在这一领域进行进一步研究的必要性和重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号