首页> 外文会议>Quantitative phase imaging III >Adaptive flow-field measurements using digital holography
【24h】

Adaptive flow-field measurements using digital holography

机译:使用数字全息的自适应流场测量

获取原文
获取原文并翻译 | 示例

摘要

Variations of the optical detection path-length in image correlation based flow-field measurements result in strong errors in position allocation and thus lead to a strong enhancement of the measurement uncertainty of the velocity. In this contribution we use digital holography to measure the wavefront distortion induced by fluctuating phase boundary, employing spatially extended guide stars. The measured phase information is used to correct the influence of the phase boundary in the detection path employing a spatial light modulator. We analyze the potential of guide stars that are reflected by the phase boundary, i.e. the Fresnel reflex, and transmitted. Our results show, that the usage of wavefront shaping enables to strongly reduce the measurement uncertainty and to strongly improve the quality of image correlation based flow-field measurements. The approaches presented here are not limited to application in flow measurement, but could be useful for a variety of applications.
机译:在基于图像相关的流场测量中光学检测路径长度的变化会导致位置分配中的严重误差,从而导致速度测量不确定性的显着增强。在这项贡献中,我们使用数字全息术,通过空间扩展的引导星来测量由波动的相界引起的波前畸变。所测量的相位信息用于校正使用空间光调制器的检测路径中的相位边界的影响。我们分析了由相边界(即菲涅耳反射)反射并传播的引导星的潜力。我们的结果表明,使用波前整形可以大大降低测量不确定度,并可以大大提高基于图像相关性的流场测量的质量。此处介绍的方法不仅限于流量测量中的应用,还可以用于多种应用。

著录项

  • 来源
    《Quantitative phase imaging III》|2017年|100740F.1-100740F.7|共7页
  • 会议地点 San Francisco(US)
  • 作者单位

    Laboratory for Measurement and Sensor System Technique, Faculty of Electrical and Computer Engineering, Technische Universitat Dresden, Germany;

    Laboratory for Measurement and Sensor System Technique, Faculty of Electrical and Computer Engineering, Technische Universitat Dresden, Germany;

    Laboratory for Measurement and Sensor System Technique, Faculty of Electrical and Computer Engineering, Technische Universitat Dresden, Germany;

    Laboratory for Measurement and Sensor System Technique, Faculty of Electrical and Computer Engineering, Technische Universitat Dresden, Germany;

    Laboratory for Measurement and Sensor System Technique, Faculty of Electrical and Computer Engineering, Technische Universitat Dresden, Germany;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Adaptive optics; digital holography; flow-field measurements;

    机译:自适应光学数字全息术流场测量;