首页> 外文会议>Proceedings of the IASTED International Conference on Energy and Power Systems >A STUDY OF DETECTION OF BROKEN ROTOR BARS IN INDUCTION MOTORS USING INSTANTANEOUS POWER
【24h】

A STUDY OF DETECTION OF BROKEN ROTOR BARS IN INDUCTION MOTORS USING INSTANTANEOUS POWER

机译:瞬时功率检测感应电动机转子断条的研究

获取原文
获取原文并翻译 | 示例

摘要

The paper demonstrates the practical implementation of the instantaneous power as diagnostic medium for condition monitoring. The analysis has been made on 2.2kW three-phase induction motors in a healthy and broken-rotor bars fault conditions at different loading conditions. It is well understood that stator current is widely used to detect the frequency sideband components for broken rotor bars. However, the practical results show the disability of stator current signal, in some cases, in detecting the sideband frequency components. Therefore, in this paper, the Fast Fourier Transform (FFT) of the instantaneous power has been used for detecting the broken rotor bar sidebands to achieve more accurate and reliable results. A modified sideband frequencies of the instantaneous power signals that reflects the condition of the motor were shown.
机译:本文演示了瞬时功率作为状态监测诊断介质的实际应用。在不同负载条件下,在健康的转子断条故障条件下对2.2kW三相感应电动机进行了分析。众所周知,定子电流被广泛用于检测转子条损坏的频率边带分量。然而,实际结果表明,在某些情况下,定子电流信号在检测边带频率分量时会失效。因此,在本文中,瞬时功率的快速傅里叶变换(FFT)已用于检测损坏的转子导条边带,以实现更准确和可靠的结果。示出了反映电动机状况的瞬时功率信号的修改的边带频率。