Temperature gradient in the LAMOST dome is the significant factor that affects the dome seeing. So, researches on some cooling projects to improve the temperature distribution in the enclosing channels must be done.Since the temperature distribution in the dome is instantaneous and extraordinary difficult to control, a transient calculation method is used with Icepak, a thermal analysis software. In the thermal calculating, two different cooling schemes based on ventilating duct, one with normal temperature air and the other with cooling air, are analyzed emphatically. Comparing with other cooling projects, the calculating result clearly indicates that the scheme with ventilating duct is better than the scheme only adopting heatsink. What's more, ventilating duct with cooling air can form a local cooling area and get an even clearer seeing, and only this temperature distribution can meet the demands. All results are helpful to the theoretical study on seeing and the design on LAMOST dome.
机译:LAMOST穹顶中的温度梯度是影响穹顶视线的重要因素。因此,必须进行一些冷却项目的研究以改善封闭通道中的温度分布。由于圆顶的温度分布是瞬时的并且非常难以控制,因此使用热分析软件Icepak的瞬态计算方法。在热计算中,着重分析了两种基于通风管道的冷却方案,一种采用常温空气,另一种采用冷却空气。与其他制冷方案相比,计算结果清楚地表明,采用通风管道的方案要优于仅采用散热器的方案。而且,带有冷却空气的通风管道可以形成局部冷却区域,并获得更清晰的视野,只有这种温度分布才能满足要求。所有的结果对LAMOST球顶的视觉研究和设计都有帮助。