An experimental programme was conducted to investigate the compressive behaviour of concrete-filled cold-formed steel tubular(CFCFST)stub columns.A total of 30 CFCFST stub columns were tested.The cold-formed square hollow section(SHS)tubes included unstiffened and longitudinally inner-stiffened sections.Normal concrete and self-consolidating concrete with a nominal compressive strength of 30MPa were used to fill the cold-formed SHS steel tubes.The effects of the stiffeners on the rigidity,ductility,failure mode and average sectional strength of the specimens were examined and analyzed.The inner stiffeners were found to affect the ductility,the failure mode and overall sectional strength of the specimens significantly.The effect of the specimens with thinner(6mm)tubes tends to be more remarkable than specimens with thicker(10mm)tubes.
机译:进行了一个试验程序来研究混凝土填充的冷弯钢管短柱的压缩性能,共测试了30根CFCFST短柱,其中冷弯方空心截面管包括未加筋的和纵向的用标称抗压强度为30MPa的普通混凝土和自固结混凝土填充SHS冷弯钢管。加劲肋对钢管的刚度,延展性,破坏模式和平均截面强度的影响。检查并分析了试样,发现内部加强筋对试样的延展性,破坏模式和整体截面强度有显着影响。(6mm)管较薄的试样比10mm较厚的试样的效果更显着)管。