This paper presents a combined method to detect islanding conditions. The method combines two approaches in a two stage process, and is based on the injection of reactive current as a disturbance to detect islanding. In the first stage, the method tests the voltage rate of change and the frequency rate of change. Once an islanding situation is presumed in the first stage, then in the second stage, a positive feedback scheme is enabled to confirm the islanding condition. This combined detection method is more effective and precise, avoids false tripping out by reducing the sensitivity to other perturbations, and avoids instabilities as the positive feedback is not connected all time. Simulations are presented to assess the performance of the proposed combined detection method.
机译:本文提出了一种检测孤岛状况的组合方法。该方法在两个阶段的过程中结合了两种方法,并且基于无功电流的注入作为干扰来检测孤岛。在第一阶段,该方法测试电压变化率和频率变化率。一旦在第一阶段中推测出孤岛状况,则在第二阶段中,启用正反馈方案以确认孤岛状况。这种组合的检测方法更有效,更精确,通过降低对其他扰动的敏感度来避免误跳闸,并避免由于不始终连接正反馈而导致的不稳定。仿真被提出以评估所提出的组合检测方法的性能。