This paper presents a combined method to detect islanding conditions. The method combines two approaches in a two stage process, and is based on the injection of reactive current as a disturbance to detect islanding. In the first stage, the method tests the voltage rate of change and the frequency rate of change. Once an islanding situation is presumed in the first stage, then in the second stage, a positive feedback scheme is enabled to confirm the islanding condition. This combined detection method is more effective and precise, avoids false tripping out by reducing the sensitivity to other perturbations, and avoids instabilities as the positive feedback is not connected all time. Simulations are presented to assess the performance of the proposed combined detection method.
机译:本文提出了一种检测岛状条件的组合方法。该方法在两个阶段过程中结合了两种方法,基于反应电流的喷射作为检测岛屿的干扰。在第一阶段,该方法测试变化的电压率和变化频率。一旦在第一阶段预测岛屿情况,那么在第二阶段,就会启用正反馈方案来确认岛屿状况。这种组合的检测方法更有效并且精确,避免通过降低对其他扰动的敏感性来避免错误绊倒,并且避免不稳定性随着肯定反馈而没有连接。提出了模拟以评估所提出的组合检测方法的性能。