Low-frequency power oscillation issues are both serious in Yunnan power grid and Southern China power grid, the two "west to east" complex and long chain configuration networks. Based on the significant data provided by the real-time monitoring system in Yunnan power grid, low-frequency issue is analyzed by Prony method, frequency, amplitude, angle and the damping ratio of system are obtained. Analysis results provide suggestions to establish restraining measures for low frequency oscillation and operation control strategy to restrain low- frequency oscillation.
机译:低频电力振荡问题在云南电网和华南电网这两个“东西向”的复杂长链配置网络中都非常严重。基于云南电网实时监测系统提供的大量数据,通过Prony方法对低频问题进行分析,得到系统的频率,振幅,角度和阻尼比。分析结果为建立抑制低频振荡的措施和抑制低频振荡的运行控制策略提供了建议。