首页> 外文会议>Power Electronics for Distributed Generation Systems (PEDG), 2012 3rd IEEE International Symposium on >Neutral-point voltage control for a three-level DC-AC inverter using equivalent-input-disturbance approach
【24h】

Neutral-point voltage control for a three-level DC-AC inverter using equivalent-input-disturbance approach

机译:采用等效输入扰动方法的三电平DC-AC逆变器中性点电压控制

获取原文
获取原文并翻译 | 示例

摘要

One problem with a single-voltage source, three-level inverter is the drafting of its neutral-point voltage. This may occur during transition or when unbalanced loads are connected to the inverter system. Variation of neutral-point voltage may greatly deteriorate the power quality. In this paper, we employ an equivalent-input-disturbance approach to deal with this problem. By adding an extra neutral leg, the control problem of neutralpoint voltage is converted to a disturbance rejection problem. This method suppresses the variation of the neutral-point voltage to a small level and reduces the capacity of capacitors. Simulation results show the effectiveness of the method.
机译:单电压源三电平逆变器的一个问题是其中性点电压的起伏。这可能发生在过渡期间或将不平衡负载连接到逆变器系统时。中性点电压的变化可能会大大降低电能质量。在本文中,我们采用等效输入扰动方法来解决此问题。通过增加一条额外的中性线,中性点电压的控制问题将转化为干扰抑制问题。该方法将中性点电压的变化抑制到很小的水平,并减小了电容器的容量。仿真结果表明了该方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号